Warning: Dryer vent lint nearly cost me a service call back in October
Had a dryer job over in Mesa back in October where the customer swore the heating element was dead because clothes came out cold after 90 minutes. I pulled the back panel and the element tested fine at 240 volts, so I started tracing airflow. Turned out the flexible vent behind the unit had a big sag in it where lint packed down into a solid mat about the size of a softball. The customer had never pulled the dryer out since they moved in, and the vent run was close to 12 feet with two elbows, which is a bad setup for lint buildup. I cleared the whole run with a vent brush and a shop vac, then swapped the foil flex for rigid pipe so it would not sag again. Cycle times dropped from 90 minutes to about 45 and the element was never the problem. Now I check airflow before I touch the meter on any no-heat call. How many of you charge extra when you find a vent run that long, or do you just quote the cleaning as its own line item?